EL-USB-TC-LCD

  • -200 to +1350°C K-type range
  • -200 to +1190°C J-type range
  • -200 to +390°C T-type range
  • Immediate, delayed and push-to-start mode
  • High contrast LCD shows last, high and low stored readings

New Product
RoHS compliant

This standalone data logger measures and stores over 32,000 temperature readings from either a K, J or T type thermocouple.

The thermocouple is attached via the thermocouple socket at the base of the unit. The user can easily set up the logger and view downloaded data by plugging the module into a PC's USB port and using the supplied software. Data can then be graphed, printed and exported to other applications.

The high contrast LCD can show several different temperature variables. The user can cycle between these using the push button. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 1 year.

Download the latest version (v5.2) of the configuration and graphing software from the link below.

This is a popular part, normally stocked in high quantity and suitable for new designs.

Qty Price Ea.
1–4 £69.95
5–9 £69.95
10–24 £69.95
25+ £58.06
 
Datasheet
Product Compliance
Download Software
Online Product Registration

You may also be interested in these related products:

BAT 3V6 1/2AA BAT 3V6 1/2AA  
Qty Price Ea.
1–4 £1.93
5–9 £1.93
10–24 £1.93
25+ £1.93
Non rechargeable battery
View BAT 3V6 1/2AA
Specification Min. Typ. Max. Unit
Probe Measurement range K-type -200 (-328)   +1350 (+2462) °C (°F)
J-type -200 (-328)   +1190 (+2174)
T-type -200 (-328)   +390 (+734)
Operating temperature range -10 (+14)   +40 (+104) °C (°F)
Resolution (internal and displayed)   0.5 (1)   °C (°F)
Accuracy (logger error)   ±1 (2)**   °C (°F)
Logging rate every 1s   every 12hr -
1/2AA 3.6V Lithium Battery Life ***   6   month

* Using thermocouple sensors, the EL-USB_TC can log temperatures as detailed above, but the data logger should not be subjected to temperatures outside the Operating temperature range
** EL-USB-TC is designed to be used whilst disconnected from USB port
*** @ 25°C and 1m logging rate